What Light-Duty Steel Metal Grating Is
Light-duty steel metal grating is a load-bearing floor panel used where traffic is limited to pedestrians, hand trucks and light carts rather than vehicles or heavy plant. It is typically fabricated as bar grating, a rigid open grid built from a series of parallel load-bearing bars joined to perpendicular cross bars. The bars are fastened by swaging, riveting, dovetailing or welding, and the resulting panel is strong in the direction of the bearing bars while remaining open in both directions.
Typical duties include pedestrian walkways, maintenance platforms, machinery floors, access catwalks, stair treads and drainage covers. The open grid drains water and debris, ventilates the space below, and presents a slip-resistant surface without the weight of a solid plate. That combination of lightness, stiffness and drainage is why light-duty grating is so common in industrial safety barriers, walkways and highway drainage platforms, for both indoor and outdoor service.
How the Designation System Works
Most light-duty bar grating follows a G-series designation that packs the three dimensions of the panel into a single code. The letter G identifies a grating, the first two or three digits give the bearing bar depth and thickness, and the two following numbers give the bearing bar pitch and the cross bar pitch. In a code such as G325/30/100, the first group G325 means a bearing bar of 32 mm depth and 5 mm thickness, the middle number 30 is the bearing bar pitch in millimetres, and the final number 100 is the cross bar pitch in millimetres.
Reading the code correctly matters because the three dimensions trade off against each other. A deeper bearing bar carries more load over a longer span, a closer bearing bar pitch spreads the load and reduces the opening, and a closer cross bar pitch stiffens the panel and improves slip resistance. A replacement panel is only interchangeable with the original when all three numbers match.
Common Light-Duty Specifications
The table below lists the bearing bar sizes normally offered for light-duty service, with the code prefix that each size produces. Bearing bar pitch is commonly 30, 40 or 60 mm and cross bar pitch is commonly 50 or 100 mm, so a full designation is formed by appending those two pitches to the prefix.
| Bearing bar size (depth × thickness, mm) | Code prefix | Common bearing bar pitch (mm) | Common cross bar pitch (mm) |
|---|---|---|---|
| 20 × 3 | G203 | 30 / 40 / 60 | 100 / 50 |
| 25 × 3 | G253 | 30 / 40 / 60 | 100 / 50 |
| 32 × 3 | G323 | 30 / 40 / 60 | 100 / 50 |
| 40 × 3 | G403 | 30 / 40 / 60 | 100 / 50 |
| 20 × 5 | G205 | 30 / 40 / 60 | 100 / 50 |
| 25 × 5 | G255 | 30 / 40 / 60 | 100 / 50 |
| 32 × 5 | G325 | 30 / 40 / 60 | 100 / 50 |
| 40 × 5 | G405 | 30 / 40 / 60 | 100 / 50 |
| 45 × 5 | G455 | 30 / 40 / 60 | 100 / 50 |
| 50 × 5 | G505 | 30 / 40 / 60 | 100 / 50 |
| 55 × 5 | G555 | 30 / 40 / 60 | 100 / 50 |
| 60 × 5 | G605 | 30 / 40 / 60 | 100 / 50 |
For example, G253/30/100 is a 25 × 3 mm bearing bar on a 30 mm pitch with cross bars at 100 mm, and G605/60/50 is a 60 × 5 mm bearing bar on a 60 mm pitch with cross bars at 50 mm. The heavier 5 mm bars are used where a longer unsupported span or a higher concentrated load is expected within light-duty service.
Materials and Finishes
Light-duty grating is most often made from carbon steel and protected by hot-dip galvanizing to ASTM A123, the standard specification for zinc coatings on fabricated steel products. Hot-dip galvanizing coats the cut edges and the inside of the joints as well as the flat surfaces, which is why it is preferred for outdoor and wet service. Mill-galvanized or painted finishes are used where the environment is dry and the appearance matters more than durability. Stainless steel grating is specified for chemically aggressive or hygienic areas such as food and pharmaceutical plants, and aluminium grating is chosen where weight must be kept to a minimum. The choice of material, rather than the grating geometry, usually sets the service life.
Selection, Installation and Safety
Span and load: size the bearing bar depth from the required span and the design load. Light-duty grating is intended for pedestrian and light cart traffic, and it should not be treated as a structural floor for vehicles.
Opening size: the bearing bar pitch and cross bar pitch set the size of the openings, which affects both slip resistance and the size of objects that can fall through. Walkway openings are normally chosen so that a small object cannot pass through.
Fixing: panels are secured with saddle clips, grating clips or welded studs at regular intervals so that the panel cannot lift or shift under foot traffic and thermal movement.
Edge protection: exposed edges and openings are usually fitted with toeboards or edge angle, and the installation should satisfy the walking-working surface requirements of OSHA 29 CFR 1910 Subpart D.
Handling: because the panels are open, corners and the ends of the bearing bars should be protected during transport to avoid a bent or twisted panel that will rock on its supports.
Frequently Asked Questions
Q: What does G325/30/100 mean?
It is a grating with a 32 mm deep, 5 mm thick bearing bar on a 30 mm bearing bar pitch and cross bars at 100 mm spacing.
Q: What is the difference between light-duty and heavy-duty grating?
Light-duty grating is sized for pedestrians and light carts, while heavy-duty grating uses deeper, thicker bearing bars and closer pitches to carry vehicles and heavy plant.
Q: Which finish should be used outdoors?
Hot-dip galvanizing to ASTM A123 is the usual choice, because it coats the cut edges and joints as well as the flat surfaces and gives the longest service life in wet conditions.
Q: How is the load capacity determined?
The capacity is set by the bearing bar depth and thickness, the unsupported span and the bar pitch, so the panel is selected from the required span and design load rather than from its size alone.
Q: Can grating panels be cut on site?
Yes, but the cut edges must be re-protected against corrosion, and the panel must be re-supported at the original spacing so that it does not deflect beyond the design limit.
Q: When is stainless steel grating preferred?
Stainless steel is preferred for chemically aggressive, wet or hygienic environments such as food and pharmaceutical plants, where carbon steel would corrode quickly.