Home-Knowledge-

Content

Zinc Coating on Galvanized Steel Sheet: G30, G40, G60, G90, Z100, Z275 and Z350 Explained

Nov 06, 2025

galvanized steel sheet

 

The zinc coating is the single most important factor determining how long a galvanized steel sheet will last in service. It protects the steel by barrier action and by sacrificial (cathodic) action at cut edges and scratches. Buyers who understand the coating designation - what the numbers mean, how mass converts to thickness, and how the environment affects service life - can specify the right product the first time and avoid both premature corrosion and unnecessary cost.

 

1.What Do G30, G40, G60, G90 and Z100, Z275, Z350 Mean?

 

Coating designations describe the mass of zinc per unit area, not the coating thickness directly. Two standards dominate the market:
 
1.1 ASTM A653 - G-series (oz/ft²)
Under ASTM A653, the coating is designated by the total zinc mass on both sides, in ounces per square foot: G30 = 0.30 oz/ft², G40 = 0.40 oz/ft², G60 = 0.60 oz/ft², G90 = 0.90 oz/ft².
 
1.2 EN 10346 - Z-series (g/m²)
Under EN 10346, the coating is designated by the total zinc mass on both sides in grams per square meter: Z100 = 100 g/m², Z180 = 180 g/m², Z275 = 275 g/m², Z350 = 350 g/m².
 
1.3 Conversion between the two systems
1 oz/ft² ≈ 305 g/m² total (both sides). The most common designations therefore align as follows:
 
Designation
Total coating (both sides)
Equivalent
G30 (ASTM)
≈ 91 g/m²
≈ Z90
G40 (ASTM)
≈ 122 g/m²
≈ Z120
G60 (ASTM)
≈ 183 g/m²
≈ Z180
G90 (ASTM)
≈ 275 g/m²
= Z275 (EN)
Z100 (EN)
100 g/m²
≈ G33
Z350 (EN)
350 g/m²
≈ G115

 

Ask for Sample & Quote

2. Coating Mass vs Coating Thickness

 

Zinc has a density of about 7.14 g/cm³. Therefore 1 µm of zinc on one side ≈ 7.14 g/m²; for both sides, 1 µm ≈ 14.3 g/m² total. Converting the common designations to average thickness per side:
 
Designation
Total g/m² (both sides)
Average thickness per side
G30 / Z90 class
≈ 91 g/m²
≈ 6.4 µm
G40 / Z120 class
≈ 122 g/m²
≈ 8.5 µm
G60 / Z180
≈ 183 g/m²
≈ 12.8 µm
G90 / Z275
275 g/m²
≈ 19.3 µm
Z350
350 g/m²
≈ 24.5 µm
 
Thickness figures are averages; the hot-dip process produces a zinc–iron alloy layer plus a pure zinc layer, and local variation is normal within the tolerances of the governing standard.

 

3. Estimated Service Life by Coating Weight and Environment

 

Corrosion of zinc in the atmosphere is usually classified with the ISO 9223 corrosivity categories, from C2 (low) to C5 (very high). The table below gives engineering estimates for time to first significant coating breakdown, combining typical zinc corrosion rates per category with the coating masses above. Treat the figures as planning estimates, not guarantees - actual life depends on microclimate, drainage, and edge conditions.
 
Coating
C2 · Low (rural, dry indoor)
C3 · Moderate (urban)
C4 · High (industrial, humid)
C5 · Very high (coastal, marine splash)
G30 / Z90 class
15–25 years
5–10 years
2–4 years
1–2 years
G40 / Z120 class
20–35 years
10–15 years
3–6 years
1.5–3 years
G60 / Z180
25–40 years
15–20 years
5–9 years
2–4 years
G90 / Z275
35–50 years
20–30 years
8–14 years
3–6 years
Z350
40 years+
30–40 years
12–18 years
5–8 years

 

4. How to Choose the Right Zinc Coating

 

4.1 Match the coating to the environment
 
Application environment
Recommended coating
Typical use
Dry indoor
Z100–Z180 / G40–G60
Indoor structures, office furniture, ducting
Moderate outdoor, low pollution
Z180–Z275 / G60–G90
Roofing, cladding, fencing in suburban areas
Urban / light industrial
Z275 / G90
Building envelopes, agricultural buildings
High humidity / heavy industrial
Z275–Z350 / G90+
Chemical plants, acid-gas zones (confirm with supplier)
Coastal (salt spray)
Z350 or pre-painted/ZnAl systems
Coastal roofing, port structures
Marine (offshore, port equipment)
Z350 minimum, or ZnAl (ZM) / Zn5Al coatings
Offshore facilities, jetties
 
4.2 Ordering checklist
 
State the standard: EN 10346 (Z-series) or ASTM A653 (G-series) - do not mix.
State the coating: e.g. Z275, and whether both sides are coated equally (e.g. Z275/Z275) or differentially (e.g. Z275/Z100).
Request the mill test certificate showing measured coating mass in g/m².
Confirm surface finish (spangle / minimised spangle / spangle-free) and passivation (chromate-free preferred).

 

info-466-292

The thickness of the zinc coating is one of the key factors that determine the service life of the galvanized steel sheet. You can choose the appropriate zinc coating according to your actual needs. The estimated service life of the common zinc coating thickness in ordinary urban construction environments is as follows:

G30 (90g/m²): about 5-10 years

G40 (120g/m²): about 10-15 years

G60 (180g/m²): about 15-20 years

G90 / Z275 (275g/m²): about 20-30 years

Z100 (100g/m²): about 10-15 years

Z350 (350g/m²): about 40 years or more

Dry indoor environment (such as indoor building structures, office furniture): 20-30 µm

Moderate outdoor environment (such as suburbs, low pollution areas): 50-60 µm

Urban or light industrial environment (moderate pollution, moderate humidity): 70-80 µm

High humidity or heavy industrial environment (such as chemical plants, acid gas areas): 85-100 µm

Coastal areas (strong salt spray, high corrosion): 100-150 µm

Marine environment (strong corrosion, such as offshore facilities, port equipment): 150 µm and above

info-499-292

As a professional steel supplier and manufacturer, GNEE STEELGroup is committed to becoming a trusted partner of customers through high-quality products and quick response. We strictly control quality, with an annual production capacity of more than 1 million tons, efficient delivery, and customized services. Our products meet international standards and meet the diverse needs of customers.

 

5. FAQ

 

Q1: Is G90 the same as Z275?
In mass terms, yes: both are approximately 275 g/m² total zinc on both sides (G90 = 0.90 oz/ft² ≈ 275 g/m²). The difference is the governing standard - ASTM A653 vs EN 10346 - so state the standard on your order.


Q2: How do I convert coating mass to thickness?
Divide by density: 1 µm per side ≈ 7.14 g/m². For total coating on both sides, 1 µm ≈ 14.3 g/m². A Z275 coating is therefore about 19 µm average per side.


Q3: How long will Z275 galvanized sheet last outdoors?
As an estimate: roughly 20–30 years in a moderate urban (C3) atmosphere before significant coating breakdown, 8–14 years in industrial/humid (C4) conditions, and less in coastal salt environments. Actual life varies with microclimate.


Q4: Is a thicker coating always better?
Not always. Heavier coatings (Z350) cost more and can reduce formability slightly; on deep-drawn parts the coating may crack or flake. Choose the coating that matches the environment and the forming operation.


Q5: Can I specify different coating weights on each side?
Yes. Differential coatings (e.g. Z275/Z100) are common for auto body sheet, where the inner face needs less protection. Specify both sides explicitly in your inquiry.

 

SEND INQUIRY