1. What Is S250GD Galvanized Steel?
S250GD (steel number 1.0242) is a structural steel grade specified in EN 10346 (continuously hot-dip coated steel strip and sheet for structural purposes). In the designation, "S" means structural steel, "250" is the guaranteed minimum yield strength in megapascals, and "GD" indicates suitability for hot-dip galvanizing. S250GD is delivered as zinc-coated (Z), zinc-iron alloy (ZF), zinc-aluminum (ZA) and aluminum-zinc (AZ) coated products, in coil, sheet and strip form, for construction, appliances and general manufacturing.
The grade is alloyed with controlled carbon and manganese, with strict limits on phosphorus and sulfur, so that the steel remains weldable and formable after the galvanizing thermal cycle. Because the mechanical properties are guaranteed on the finished coated product, S250GD is a dependable choice where structural performance and corrosion resistance must be verified against a written standard.
2. Chemical Composition (per EN 10346, max values)
| Element | Maximum content (%) |
|---|---|
| Carbon (C) | 0.20 |
| Manganese (Mn) | 1.70 |
| Phosphorus (P) | 0.10 |
| Sulfur (S) | 0.045 |
| Nitrogen (N) | 0.012 |
EN 10346 does not specify a silicon limit for S250GD; if a silicon cap is required for a specific painting or welding application, confirm it with the mill and record it in the purchase order.
3. Mechanical Properties (EN 10346, minimum values)
| Grade | Yield strength (MPa) | Tensile strength (MPa) | Elongation A80 (%), t≤0.7 mm / t>0.7 mm |
|---|---|---|---|
| S250GD+Z / ZF / ZA / ZM / AZ / AS | ≥250 | 330-430 | 17 / 19 |
| S220GD (comparison) | ≥220 | 300-420 | 18 / 20 |
| S280GD (comparison) | ≥280 | 360-460 | 16 / 18 |
| S350GD (comparison) | ≥350 | 420-520 | 14 / 16 |
Bending: S250GD meets the bend test requirements of EN 10346 with a bending diameter of 1a (a = sheet thickness) for the standard thickness range, which is the accepted verification of coating adhesion and substrate ductility.
4. Coating, Surface and Supply Options
| Item | Typical availability |
|---|---|
| Governing standard | EN 10346 (current); also supplied to JIS G3302 or ASTM A653 by agreement |
| Coating types | Z (pure zinc), ZF (zinc-iron alloy), ZA, AZ, AS |
| Zinc coating mass | Z100 - Z600 g/m² (total both sides); lighter classes on request for indoor use |
| Thickness | 0.12 - 6.00 mm |
| Width | 600 - 1500 mm (slitting available) |
| Surface treatment | Passivation (C), oiling (O), lacquer sealing (L), phosphating (P), untreated (U) |
| Surface structure | Normal spangle (NS), minimized spangle (MS), spangle-free (FS) |
| Coil ID | 508 mm / 610 mm |
| Documentation | Mill test certificate (EN 10204 3.1/2.2); independent third-party inspection on request |
5. Advantages and Typical Applications
Guaranteed structural strength: a minimum yield strength of 250 MPa supports load-bearing design in light steel structures, purlins, profiles and framing.
Good formability: elongation and bend performance are sufficient for roll forming, press braking and cold bending of sections without cracking.
Corrosion resistance: with appropriate coating classes, S250GD serves for decades in outdoor and industrial environments; heavier coatings (Z275+) are recommended for coastal or high-pollution sites.
Weldability: low carbon equivalent allows standard MIG/TIG and resistance welding without preheating for common thicknesses; remove zinc near the weld line and ventilate against zinc fumes.
Sustainability: steel and zinc are both highly recyclable; the long service life reduces lifecycle material consumption.
Applications: cold-formed steel sections and purlins, roofing and wall systems, garage doors, agricultural buildings, racks and storage systems, bus shelters, fencing, and structural components for machinery housings.
6. Packaging and Shipping
Standard export packaging for galvanized coil: inner kraft paper, a water-vapor barrier film in the middle layer, and outer protection, with the coil secured by steel strapping and edge protectors; an inner coil sleeve (ID 508/610 mm) protects the bore. Sheets are packed on strong pallets or wooden crates with waterproof covering. Coils are loaded by crane into containers or by lashing on flat racks, with dunnage and waterproof covers for sea transport. Typical production-to-shipment lead time is 15-25 days depending on coating class and quantity; confirm the exact schedule in the sales contract.
Frequently Asked Questions
What is the difference between S250GD and DX51D? DX51D is a cold-forming grade without guaranteed yield strength, optimized for bending and stamping of non-structural parts. S250GD is a structural grade with a guaranteed minimum yield strength of 250 MPa, intended for load-bearing members. Use S250GD where design calculations require certified mechanical properties.
Which standards apply to S250GD today? The current European standard is EN 10346, which replaced the older EN 10147 and EN 10142 in 2009. When you see EN 10147 or EN 10142 on old datasheets, treat the data as outdated and request a certificate against EN 10346.
What zinc coating class should I choose for structural outdoor use? For outdoor structures, Z275 g/m² is a common default in Europe; heavier classes (Z350-Z600) are used in coastal or highly corrosive industrial environments. Lighter classes such as Z100-Z180 suit sheltered or indoor applications with controlled humidity.
Can S250GD be welded? Yes. The low carbon content makes it weldable with standard MIG/MAG and TIG processes. Grind or brush the zinc coating 20-30 mm from the weld line, use appropriate ventilation or fume extraction because zinc vapor is hazardous, and apply zinc-rich paint to the welded area after welding to restore corrosion protection.
How is coating mass verified on delivery? Coating mass is verified by the weigh-strip method (weighing a sample before and after zinc stripping) per the governing standard, or by magnetic gauge measurement. The mill test certificate records the triple-spot and single-spot values; independent third-party inspection can witness sampling at the mill or port.