Walkway and catwalk grating is an open grid of parallel bearing bars crossed by perpendicular cross bars. The grid carries foot traffic, equipment and maintenance loads while letting light, air, water and debris pass through, which is why it is used on industrial platforms, access walkways, catwalks, stair treads and trench covers. Pressure-locked construction forms the connection between the two bar directions by mechanical deformation rather than by welding.
What Pressure-Locked Steel Grating Is
In pressure locking, notches are cut into the top edge of each bearing bar and the cross bars are forced into those notches under high pressure, so the displaced metal of the bearing bar grips the cross bar and locks the panel into a single rigid grid. No filler metal is added and no heat is applied, so the joint retains the full coating and there is no heat-affected zone or weld spatter to touch up.
The load path runs mainly through the bearing bars, which span between supports in one direction, while the cross bars hold the bearing bars upright and distribute concentrated loads between adjacent bars. A pressure-locked panel is therefore stiff in one direction only, and the direction of the bearing bars must be checked against the supporting steelwork before delivery.
Pressure Locking Compared with Welding and Riveting
| Manufacturing method | Joint type | Characteristics | Typical use |
|---|---|---|---|
| Pressure-locked | cross bar pressed into bearing bar notches, no weld | clean surface, no heat-affected zone, coating stays intact | platforms, walkways, catwalks |
| Welded | cross bar resistance-welded to bearing bar | high joint stiffness, suitable for the heaviest loads | industrial floors, heavy platforms |
| Riveted | pressed cross bars retained by rivets | mechanical fastening now largely superseded | legacy and special fabrications |
| Swage-locked | cross bar trapped in a deformed bearing bar slot | smooth walking surface with good rigidity | architectural and screening panels |
For most walkway and catwalk duty the pressure-locked panel is the economic choice, because the joint needs no re-coating and the panel can be cut to width on site. Welded grating is preferred where vehicle wheels, trolley loads or very heavy point loads demand maximum joint rigidity.
Bearing Bar Size, Pitch and Load Capacity
The load capacity of a panel is set by the bearing bar depth and thickness, the bearing bar pitch, the cross bar pitch and the unsupported span. Common bearing bar sections run from 20 x 3 millimetres for light walkway duty to 60 x 5 millimetres or heavier for vehicle traffic, with cross bar pitches of 50 or 100 millimetres.
| Bearing bar (mm) | Typical bearing bar pitch | Indicative duty |
|---|---|---|
| 20 x 3 to 25 x 3 | 30 to 40 mm | light walkways and screens |
| 30 x 4 to 32 x 5 | 30 to 40 mm | general access walkways and catwalks |
| 40 x 5 to 50 x 5 | 30 to 40 mm | industrial platforms, trolley traffic |
| 60 x 5 and above | 30 mm | heavy duty floors, trench covers, vehicle loads |
Capacity is read from the load tables produced to NAAMM MBG 531 or the equivalent national tables for steel grating, which give the allowable uniform and concentrated load for each span. Pedestrian walkway design is normally checked against a concentrated load applied over a small contact area, commonly about 2.2 kilonewtons on a 100 x 100 millimetre patch, together with deflection limited to about one two-hundredth of the span unless the project states a tighter criterion.
Walkway, Catwalk and Stair Tread Configurations
Flat bar grating gives the cleanest surface and the simplest fabrication, and is standard for walkway platforms and mezzanine floors.
Serrated grating carries a toothed top edge on the bearing bars, raising slip resistance where the surface is oil-wet, and is the usual choice for catwalks around process equipment.
Stair treads combine a serrated or plain bearing bar panel with an abrasive or checkered nosing and, in many designs, a pair of end plates drilled for stringer fixing.
Plank and I-bar grating use a shaped or deep-section bar to raise stiffness without extra weight, and are often selected for long, narrow spans such as cable trench covers.
Loose and fixed panels are held down with saddle clips or hold-down clamps using at least four fixings per panel, with intermediate fixings spaced at roughly 1.2 metres along long spans.
Where slip resistance is specified, the requirement is usually expressed as a barefoot or shod ramp classification such as R10 to R12 under DIN 51130, which serrated surfaces achieve more readily than plain bar.
Finish, Installation and Inspection
After fabrication the panels are hot-dip galvanized to ASTM A123 or ISO 1461, producing a coating that is graded by bar thickness and typically averages 70 to 85 microns, which is thick enough to resist abrasion from foot traffic and wheel contact. Where chlorides, acids or food-grade cleanliness are involved, type 304 or 316 stainless steel is specified instead of a coating.
Installation requires level supports, correct panel orientation and fastenings tightened so that the grating cannot move or lift under foot. On delivery the panel dimensions, bar spacing, panel squareness and the lock or weld integrity should be checked, and the galvanized coating thickness confirmed with a magnetic gauge against the specified coating grade. Cutting on site is normally done by abrasive disc and the cut edges are dressed with a zinc-rich repair coating.
Frequently Asked Questions
Q: What is pressure-locked steel grating?
It is a steel grating in which cross bars are pressed into notches in the bearing bars under high pressure, forming a rigid mechanical joint without any welding or filler material.
Q: Is pressure-locked grating as strong as welded grating?
For normal walkway and catwalk loads it performs equally well. Welded grating is preferred where wheel loads, trolley traffic or very heavy point loads require the stiffest possible joint.
Q: What bearing bar pitch should be used for a walkway?
Most walkways use a bearing bar pitch of 30 to 40 millimetres with a 50 or 100 millimetre cross bar pitch; the final choice follows the load table for the actual span and load.
Q: How is the load capacity of grating verified?
The bearing bar size, pitch and span are read against published load tables as set out in NAAMM MBG 531 or the equivalent national standard, and deflection is checked against the project criterion.
Q: How thick is the galvanizing on steel grating?
Hot-dip galvanizing to ASTM A123 or ISO 1461 is graded by bar thickness and averages roughly 70 to 85 microns, so it withstands abrasion from foot traffic and resists atmospheric corrosion for decades.
Q: Which grating surface should be used where floors are oily?
Serrated grating is the normal answer for oil-wet or wet process areas, because the toothed bearing bar edge provides the slip resistance classified in ramp tests such as DIN 51130.